Digital Meters
Economic Mutifunction Meter [MFM383A]
Economic Mutifunction Meter [MFM383A]

requestquote
Display Type LCD with Backlight
Display Configuration 3 Rows of 4 Digits, 1 Row of 7 ½ Digits
Electrical Connection 3¢ - 3W, 3¢ - 4W, 2¢ - 3W, 1¢ - 2W
Type of Output Pulse Output
Features Password Protection, Energy (Active / Reactive / Apparent)
Communication Protocol RS485 and MODBUS RTU
CT Primary 1 / 5A to 10kA (Programmable for Any Value)
CT Secondary 1 / 5A (Programmable)
PT Primary 100V to 10kV (Programmable for Any Value)
PT Secondary 100V to 500V AC (L – L) (Programmable for Any Value)
Rated Input Current Nominal 5A AC (Min - 11mA Max - 6A)
Supply Voltage 100 to 240V AC (-15% to +12%) (45/65Hz)
Size 96 x 96mm
Mounting Type Panel Mount
Certification CE, UL Listed

Max/Min Demand, Phase Angle Detection [MFM376-230V]
Max/Min Demand, Phase Angle Detection [MFM376-230V]

requestquote
Display Type 7 Segment LED Display
Display Configuration 3 Rows of 4 Digits
Electrical Connection 3¢ - 3W, 3¢ - 4W, 2¢ - 3W, 1¢ - 2W
Type of Output Pulse Output
Features Phase Angle Detection, (Max/Min) Demand Power, Run Hour, Auxiliary Interrupts
CT Primary 1 / 5A to 10kA (Programmable for Any Value)
CT Secondary 1 / 5 A (Programmable)
PT Primary 100V to 500kV (Programmable for Any Value)
PT Secondary 100V to 500V (Programmable for Any Value)
Rated Input Current Nominal 5A AC (Min – 14mA, Max – 6A)
Supply Voltage 240V AC (-15% to +12%) (45/65Hz)
Size 96 x 96mm
Mounting Type Panel Mount

Din Rail, 2 Pulse Outputs, Active/ Reactive Energy, Split Load [MRJ4M-SL]
Din Rail, 2 Pulse Outputs, Active/ Reactive Energy, Split Load [MRJ4M-SL]

requestquote
Display Type 7 Segment LED Display
Display Configuration 3 Rows of 4 Digits
Electrical Connection 3Ø - 3W, 3Ø - 4W, 2Ø - 3W, 1Ø - 2W
Type of Output Pulse Output
Features Phase Angle Detection, (Max/Min) Demand Power, Run Hour, Auxiliary Interrupts
CT Primary 1 / 5A to 10kA (Programmable for Any Value)
CT Secondary 1 / 5 A (Programmable)
PT Primary 100V to 500kV (Programmable for Any Value)
PT Secondary 100V to 500V (Programmable for Any Value)
Rated Input Current Nominal 5A AC (Min – 14mA, Max – 6A)
Supply Voltage 240V AC (-15% to +12%) (45/65Hz)
Size 96 x 96mm
Mounting Type Panel Mount

Analog Meters
0 to 300V,500V,600V Measurement, Size : 96 x 96mm [AM-V-3]
0 to 300V,500V,600V Measurement, Size : 96 x 96mm [AM-V-3]

requestquote
Pointer Knife Edge Pointer
Pointer Deflection 0 to 90 degree
Scale Characteristics Non Linear Scale
Measuring Voltage Range 0 to 300V,500V,600V
Accuracy Class 1.5
Frequency 50/60Hz
Certification CE, RoHS

Current Transformers
Bus Bar Type Current transformer [SPCT]
Bus Bar Type Current transformer [SPCT]

requestquote
Features Applicable for bus bar with aperature upto 100mm
Rated Primary Rating 30 to 4000A
Rated Secondary Output 5A
Rated Burden (VA) 1/1.25/1.5/2.5/3/3.75/5/7.5/5/10/15
Accuracy 0.5/1/3/5
Operating Frequency AC 50Hz / 60Hz
System Voltage 720V Maximum
Mounting Panel Mount/DIN Rail Mount (Optional Accessory )
Certification CE
Applicable Standard IEC 61869-2
Built in VAF, Dual Colour Backlight, RS485 Communication MODBUS RTU Protocol [APFC148]
Built in VAF, Dual Colour Backlight, RS485 Communication MODBUS RTU Protocol [APFC148]

requestquote
Display Type LCD with Dual Colour Backlight
Display Configuration 3 Lines of 4 Digits to Show Electrical Parameters
Input Type 3Ø-4 Wire, 3Ø-3 Wire, 2Ø-2 Wire, 1Ø-2 Wire
Frequency 45-65 Hz
CT Primary 1/5A to 9999A (Programmable for any Value)
CT Secondary 1 or 5 A (Programmable)
PT Primary 100V to 500kV AC (Programmable for any Value)
PT Secondary 100 to 500V AC (Programmable for any Value)
Accuracy Power Factor:±0.01, Voltage (L-N/L-L), Current: ±0.5% of full scale,
Frequency – For L-N>20V, For L-L>35V: ±0.1% of full scale,
Power (kW,kVA,kVAr), Energy (kWh,kVAh,kVArh): Class 1, Temperature : ±3° of full scale
Max Number of Steps 12/14* (FAN & ALARM Output Can be Used as 13th and 14th Step)
Communication Protocol Modbus RTU (RS485 Interface)
Supply Voltage 90 to 550V AC
Bezel Size 144 x 144mm
Mounting Type Panel Mount
Line Monitoring
Phase Sequence Relay, 17.5mm [600PSR]
Applications :
  • Escalators, Elevators, Hoist, Cranes
  • DG set Panel
  • Air-Conditioning and Refrigeration Equipment

Phase Sequence Relay, 17.5mm [600PSR]

requestquote
Measuring Parameter Phase Sequence, Phase Failure, Phase Asymmetry
Electrical Connection 3Ø - 3W
Time Ranges Power On Delay: 200msec
Accuracy Trip Accuracy : ± 10V
Output Contact 1 C/O ( SPDT )
Output Rating NC: 3A @ 250V AC , NO: 5A @ 250V AC
Operating Voltage 154 To 500V AC (L - L)
Size 17.5mm
Mounting Type DIN Rail Mount
Certification CE

Current Protection
1Ø -Digital Current Protection Relay [900CPR-1-230V]
Applications :
  • Monitoring of Lighting Systems
  • Heating Circuits
  • Machine Control

digital-current-protection-relay-900cpr-1-230v

requestquote
Measuring Parameter Under Current, Over Current Protection for 1Ø System
Electrical Connection 1Ø-2W
Display 3 Digit Liquid Crystal Display
CT Setting CT Primary: 1A/5A – 999A, CT Secondary: 1A/5A (selectable)
Time Ranges Power ON Delay: 0.5 – 99.9s,Trip Time Delay: 0 – 99.9s
Recovery Time Delay: 0 – 99.9s, Response Time: < 200ms
Accuracy Current: ±1% of setting ± 2 digit, Time Setting Accuracy: ±5% of setting ± 100ms
Output Contact 1 C/O (SPDT)
Output Rating NO: 5A, 250V AC, NC: 3A, 250V AC
Supply Voltage 230V AC ±15%
Size 35 mm
Mounting Type DIN Rail Mount

Earth Leakage
Analog Earth Leakage Relay [ELRA2M]
Applications :
  • Feeders, Motors, Transformers
  • Oil Refineries, Cement Plant, Steel Plant
  • Chemical Plant, Pulp Industries
  • Mining & Control Engineering

Analog Earth Leakage Relay [ELRA2M]

requestquote
Measuring Parameter Monitors True RMS Earth Leakage Current (upto 30A )
Electrical Connection 1Ø-2W, 3Ø-4W, 3Ø-3W
Trip Setting 30mA - 30A
Time Ranges Trip Time Delay: 0 to 9 sec (NA when In=0.03A)
Accuracy Trip: ± 5% of Set Trip Current, Time: ± 5% of set Time + Response Time
Output Contact 1 C / O (SPDT )
Output Rating NO / 10A@277V AC / 28DC(1)
Supply Voltage 230V AC (±15%)
Size 35mm
Mounting Type DIN Rail Mount
Certification CE

Earth Fault
Digital Earth Fault Relay with Backlight [900EFR-BL-U]
Applications :
  • Generator Panels
  • Synchronizing Control Panels
  • Air Circuit Break

Digital Earth Fault Relay with Backlight [900EFR-BL-U]

requestquote
Measuring Parameter Earth Fault Current Monitoring
Electrical Connection 3Ø-4W, 1Ø-2W, 3Ø-3W
Display 3 Digits Liquid Crystal Display with Backlight
Trip Setting 10% to 80% of Selectable MCCB Frame Rating
Time Ranges Response Time: 100ms, Trip Time Delay: 0-99.9sec,
Recovery Time Delay: 0-99.9sec (In Auto Reset Mode), Power ON Delay: 0.5-99.9sec
Accuracy Current : 5±% of the settings ±2digit Time : ±5% of the settings ± 100ms
Output Contact 2 X 1 C/O (SPDT)
Output Rating NC: 3A@250V AC, NO: 5A@250V AC
Supply Voltage 85 to 270V AC / DC
Size 35mm
Mounting Type DIN Rail Mount
Certification CE

Motor Protection
Analog Motor Protection Relay, Auxiliary 415V [MPR-3M-415V]
Applications :
  • Control Panels
  • Feeder / Motor, Generator
  • Transformer
  • Electrical Distribution

Analog Motor Protection Relay, Auxiliary 415V [MPR-3M-415V]

requestquote
Measuring Parameter Overload Current, Phase Asymmetry, Phase Failure, Phase Sequence & Under Current
Electrical Connection 3Ø-3W
Display 3 LED Indication
Trip Setting Phase Unbalance: 50% of Motor Current (Fixed), T(sec ) Setting: To Select 2sec, 4sec, 6sec, 8sec,10sec Trip Time Curve in Overload Trip Curve Graph, Under Current: 50% of Motor Current, X Imax: To Select Motor Current Rating
Time Ranges Single Phase Trip: 5sec, Phase Unbalance: 5sec, Phase Sequence: 5sec, Overload Trip: as Per Graph 1, Under Current Trip: 5sec
CT Setting 10A, 40A, 80A
Accuracy Trip: ±5% of Set Value, Time: ±5% of Setting ±100ms
Output Contact 2 C/O (DPDT)
Output Rating NC: 5A@240V AC, NO: 5A@240V AC
Auxillary Supply 415V AC (±15%)
Size 52.5mm
Mounting Type DIN Rail Mount

Level Controller
Water Level Controller [WLCA2M1]
Applications :
  • Booster Pump Control Panels
  • Water Distribution Pumps House
  • Suitability for Water Cooled Machines

Water Level Controller [WLCA2M1]

requestquote
Features Used for Drain & Fill Control, 3 Nos Stainless Steel Prods
Trip Setting According to The Level of Sensor Placed in The Water Tank
Electrical Connection Auxiliary Supply
Display 2 LED Indication
Sensitivity Setting 1Kohms – 200Kohms
Time Ranges 0.5sec (approx)
Output Contact 1 C/O (SPDT)
Output Rating 10A@250V AC / 28V DC
Auxiliary Supply 85 to 270V AC / DC
Size 35mm
Mounting Type DIN Rail Mount
Certification CE
PLC
Applications :
  • Rinsing Filling and capping
  • Cone filling
  • Vacuum Packaging Machine
  • Goods elevator
  • Environmental chamber
  • Packing Industry

Graphical Text Display [Flexys GT35]
Graphical Text Display [Flexys GT35]

requestquote
Display Types 3.5" LCD With Touch Screen + 6 Keys (5 User Configurable)
Size 99 x 99mm
Digital Inputs 4 Digital Inputs On Power Supply Cards + As Per Flexys Card Selection
Analog Inputs As Per Flexys Card Selection
Digital Outputs As Per Flexys Card Selection
Analog Outputs As Per Flexys Card Selection
No. of Slots 3
RTC With Time Switch Function Available
Code Memory 256KB
Communication Interface RS485 Based MODBUS RTU Protocol
Expansion Yes
Supply Voltage 180-270 VAC, 50/60 Hz
Mounting Type Panel Mount

7 Segment Display & LED Indication [Flexys Rail]
7 Segment Display & LED Indication [Flexys Rail]

requestquote
Display Types 12 LEDs To Indicate Card And Communication Status For Selectable Slot, One 7 Segment To Display Slot No.
Size 140 x 93.6mm
Digital Inputs 4 Digtal Inputs On Power Supply Card + As Per Flexys Card Selection
Analog Inputs As Per Flexys Card Selection
Digital Outputs As Per Flexys Card Selection
Analog Outputs As Per Flexys Card Selection
No. of Slots 4
RTC With Time Switch Function Available
Code Memory 351KB
Communication Interface RS485 Based MODBUS RTU Protocol, Proprietary Protocol
Expansion Yes
Supply Voltage 180-270 VAC 50/60 Hz, 18 - 26 VDC
Mounting Type Din Rail

HMI
Applications :
  • Jar Filling Machine
  • Automatic FIRE Suppression System
  • Ultrasonic Cleaning Machine
  • Extrusion Machine

7' Touch Screen HMI [SP112-GT70]
7' Touch Screen HMI [SP112-GT70]

requestquote
Display Type 7" LCD Screen (65536 colors)
Resolution 800 x 480 Pixels
User Memory 128MB Flash + 64MB DRAM
Supply Voltage 24 VDC
Data logging Inbuilt ( Upto 100000 logs )
Display Configuration 7" Resistive Touch Screen
Size 203 x 149mm
Communication Serial : COM1 (RS485), COM2 (RS232 /RS485)
Ethernet : ETH PORT(10M / 100M Self Adaptation)
USB : USB Port (USB 2:0)
Real Time Clock (RTC) Yes
Data Logging Yes
Recipes Yes
Alarms Yes
Password Yes
Ingress Protection IP65
Working Temperature 0°C to 50°C

7' Touch Screen HMI [SP11-GT70-V2]
7' Touch Screen HMI [SP11-GT70-V2]

requestquote
Display Type 8 Bit Colour, LCD Backlight
User Memory 16 MB
Supply Voltage 18-30V DC
Data logging 2 GB (External SD Card)
Display Configuration 7" Resistive Touch Screen
Keys 7 Functions Keys + 1 System Key
Size 214 x 160mm
Communication COM1: RS485 Port, Protocol: MODBUS RTU, Configuration: Master
COM2: RS485 / RS232 Port, Protocol: MODBUS RTU, Configuration: Slave,(Selectable via Jumper)
COM3: RS232 Port, Protocol: ESC/PAUSE, Configuration: Serial printer (Slave)
COM4: Port: USB, Protocol: USB 2.0, Configuration: Slave
Real Time Clock (RTC) Yes

Accessories
Applications :
  • To enhance the IO Configuration of PLC

Expansion Slot – Flexys IO Cards [EXP-FLEX 2M]
Expansion Slot – Flexys IO Cards [EXP-FLEX 2M]

requestquote
Display Type LED Indication For Power ON & Communication Status
Digital Inputs As Per Flexys Card Selected
Digital Outputs As Per Flexys Card Selected
Output Ratings 5A @230VAC / 24VDC (Relay) Source Type 100mA @24VDC (Transistor)
Analog Inputs As Per Flexys Card Selected
Analog Outputs As Per Flexys Card Selected
Communication Interface RS485 Proprietary Protocol
Supply Voltage 18 - 26 VDC
Size 35 x 90mm
Mounting Type DIN Rail

vfd
FD100 [VFD, Single & 3 Phase, [FD100]]
FD100 [VFD, Single & 3 Phase, [FD100]]

requestquote
AC Input Voltage Range Single Phase :220VAC, 3 Phase: 415 VAC
Frequency Range 50/60Hz
Control Mode 4 Digital Inputs On Power Supply Cards + As Per Flexys Card Selection
Frequency Control range 0.1 ~ 400 Hz
Acc. / Dec. time 0-3600 secs
Overload capacity G Type - 150% rated current for 1 min. P type - 120% rated current for 1 min
Operation Commands Keypad and External terminals
Protection functions Over Current
Over Voltage
Under Voltage
Over heat
Overload
Phase loss
Ingress Protection IP65
Working Temperature -10°C to 50°C
Time Switches
Applications :
  • Street Light
  • Alarm / Bells
  • Signbords
  • AC Control
  • High Mast Lighting
  • Water Sprinkling
  • Motor / Pump Control

50 ON-OFF Steps, 16A Relay Output [TS2M1-1-16A]
50 ON-OFF Steps, 16A Relay Output [TS2M1-1-16A]

requestquote
Display Type Text LCD (Without Backlight)
Relay Contact 1 C/O SPDT
Operation Period 1 Week
Features 50 ON-OFF Steps Per Day, Indications: Auto Manual, Holiday, Relay Status, Day Of Week, Programming Mode.
Supply Voltage 230V AC, 110V AC
Size DIN 35mm
Mounting Type DIN Rail Mount
RTC Accuracy 15 Minutes A Year
Certification CE

Timer
Applications :
  • Starters / Control Panel
  • Injection Moulding Machinery
  • Stone Processing Machinery
  • Ball Mill Application
  • Offset Printing Industries
  • Rubber Processing Industry
  • Textile

2 Functions, 8 Time Ranges [642SQ-A]
2 Functions, 8 Time Ranges [642SQ-A]

requestquote
Operating Modes ON Delay / Interval
Range 0-3sec / min
0-10sec / min
0-30sec / min
0-60sec / min
Resolution 0.3 sec
Accuracy Setting: ± 5% of F.S
Repeat: ± 0.5% (Full Scale)
Relay Contact 1C/O SPDT
Contact Rating 5A @ 250V AC or 24V DC
Supply Voltage 230V AC, 24V AC / DC
Size 17.5mm
Mounting Type DIN Rail Mount

13 Functions, 10 Time Ranges [600XU]
13 Functions, 10 Time Ranges [600XU]

requestquote
Operating Modes On Delay, Interval, Cyclic equal OFF first, Cyclic equal ON first, Pulse output (50msec), Delay on Break, Delay on Make/ Delay on Break, Interval after Break, Single shot, Retriggerable single shot, Latching relay, Delay on make with totalise, Interval with totalise
Range 0.1-1 sec/min/hr, 0.3-3 sec/min/hr, 1-10 sec/min, 3-30 sec/min
Resolution 0.1 sec
Accuracy Setting: ± 5% of F.S., Repeat: ± 0.5% (Full Scale), Pause Time Accuracy: ± 5% , ± 5ms
Relay Contact 1 C/O SPDT
Contact Rating 5A @ 250V AC or 24V DC
Supply Voltage 20 to 240V AC, 12 to 240V DC
Size 17.5mm
Mounting Type DIN Rail Mount
Certification CE, UL
Automatic Power Factor Controllers
Applications :
  • Textile Industries
  • Printing Industries
  • Hospitals
  • Food Processing Industries
  • Automobile Industries
  • CNC Machines

Built in VAF, Dual Colour Backlight, RS485 Communication MODBUS RTU Protocol [APFC148]
Built in VAF, Dual Colour Backlight, RS485 Communication MODBUS RTU Protocol [APFC148]

requestquote
Display Type LCD with Dual Colour Backlight
Display Configuration 3 Lines of 4 Digits to Show Electrical Parameters
Input Type 3Ø-4 Wire, 3Ø-3 Wire, 2Ø-2 Wire, 1Ø-2 Wire
Frequency 45-65 Hz
CT Primary 1/5A to 9999A (Programmable for any Value)
CT Secondary 1 or 5 A (Programmable)
PT Primary 100V to 500kV AC (Programmable for any Value)
PT Secondary 100 to 500V AC (Programmable for any Value)
Accuracy Power Factor:±0.01, Voltage (L-N/L-L), Current: ±0.5% of full scale,
Frequency – For L-N>20V, For L-L>35V: ±0.1% of full scale,
Power (kW,kVA,kVAr), Energy (kWh,kVAh,kVArh): Class 1, Temperature : ±3° of full scale
Max Number of Steps 12/14* (FAN & ALARM Output Can be Used as 13th and 14th Step)
Communication Protocol Modbus RTU (RS485 Interface)
Supply Voltage 90 to 550V AC
Bezel Size 144 x 144mm
Mounting Type Panel Mount